 March 2, 2007 | AC Analytical Controls® (AC) announces a new brochure on the AC DHA Solutions based on the new Agilent Technologies 7890 gas chromatograph NEW CONFIGURATION The Detailed Hydrocarbon Analyzers (DHA) use an Agilent Technologies gas chromatograph equipped with:
- A di-methyl silicone capillary column
- A split/splitless (S/SL) injector
- A flame ionization detector
- An automatic liquid sampler
You can select either the new Agilent 7890 GC or the more compact 6850 GC.
FULL RANGE OF APPLICATIONS The AC DHA applications are dedicated to characterizing the composition of petroleum streams and comply with ASTM methods D 5134, D 6729, D 6730 and D 6733. The AC product range also includes a fast DHA application to determine the individual components in gasoline blending feedstocks within 28 minutes. The DHA Front End (FE) application complies with IP PM-DL to characterize the C1-nC9 fraction in crude oil.
FLEXIBLE DATA SYSTEMS The DHA applications will offer you flexibility in selecting a gas chromatographic data system. The DHA Plus software operates on various chromatographic data systems:
* LineUp tool not included
UNIQUE COMBI DESIGN The AC DHA Combi design allows analysts to combine two DHA applications into one Agilent 7890 GC. Using the unique AC Combi inlet, the DHA Combi Analyzer includes both the DHA Front End application for light end analysis in crude oil and one of the following standard ASTM test methods: D 6729, D 6730, D 6733 or the AC Fast DHA application.
FEATURES & BENEFITS
-
Full range of DHA application comply with ASTM D 5134, D 6729, D 6730 and D 6733
-
LineUp tool automates signal alignment to improve peak identification
-
Unique Combi system permits the analysis of both light petroleum streams and the light end in crude oil
-
DHA Front End application uses the AC pre-fractionator for the analysis of light end in crude oil conform IP PM-DL
-
Application is available on the new Agilent Technologies 7890 GC and the compact 6850 GC
-
Analyzer is compatible with major chromatographic data systems
-
Merge software easily integrates DHA Front End analysis into high temperature SIMDIS crude oil results
-
Predefined settings per sample type contribute to reliable peak identification
-
Special toolbar button automatically starts the LIMS interface
-
Each system is factory-tuned for the methods specified
-
A global network of AC certified support engineers installs the system on-site
-
One year hardware and application warranty includes free helpdesk
-
Optional online remote support by LAN connection is available
Click here to view a copy of the new DHA brochure
|
|
|
AC E-Letter Issue 3/2007
|
 In the third e-letter you will find information on keeping your system in optimal condition, the new All In One Biodiesel analyzer, the AC Hi-Speed RGA analyzer and an invitation for the Gulf Coast Conference and Beijing Conference and Exhibition on Instrumental Analysis.
Read more
|
 |
|
AC E-Letter Issue 2/2007
|
 In the second e-letter you will find information on the new All In One Biodiesel analyzer, GAS Analysis Software Excellence for multilevel calibrations and gas properties calculation, upcoming shows and the new brochures.
|
 |
|
AC E-Letter Issue 1/2007
|
 In the first e-letter you will find information on the new automated Triple A Gas Sampler, the AC solutions based on the new 7890 GC, the new brochures on the AC DHA & SIMDIS analyzers and a invitation to visit AC at the Gulf Coast Conference and the Beijing Conference.
Read more 
|
 |
|
AC E-letter Issue 2/2006
| |

In the second e-letter you will find information on the new AC Sulfur Analyzers, the AC solution for an accurate Crude Oil analysis, the new issue of the Scope of AC Analyzers and the range of AC Biodiesel Analyzers.
|
 |
|
Subscribe
|
To subscribe for the AC E-letter click here
|
 |
|